Engine Room English
 


Engine Room English: A Practical Self-Study Handbook for Marine Engineers       ,     .

   ,   ,             PSC?

  15 ,     , , ,  , , ,     .

       ,  ,    ,     .

    ,     .

             .





 

Engine Room English



BALTIC LANGUAGE CENTRE

ENGINE ROOM

ENGLISH

    

15 Chapters    Technical Vocabulary    Practical Dialogues

Exercises    Answer Keys



Baltic Language Centre

2026



PUBLICATION INFORMATION /   

Engine Room English: A Practical Self-Study Handbook for Marine Engineers

Publisher / : Baltic Language Centre

Website / : https://english-blc.ru

Year /  : 2026

ABOUT THIS HANDBOOK /  

This bilingual self-study handbook is designed to develop practical Maritime English for marine engineers. It includes technical vocabulary, operational dialogues, workplace scenarios, exercises and answer keys.

          .    ,  ,  ,     .

IMPORTANT NOTICE / 

This handbook is intended solely for Maritime English language learning and self-study. Technical examples, dialogues and emergency scenarios are illustrative and must not be used as operating instructions or authorization to perform work. Always follow the vessels approved procedures, Safety Management System (SMS), risk assessments, permits to work, manufacturers instructions and applicable requirements. Equipment operation, maintenance, isolation and emergency response must be carried out only by authorized personnel in accordance with vessel-specific procedures.

          .  ,                   .     ,    (SMS),  , -,     . , ,                 .

 2026 Larisa Brovtsina. All rights reserved. /   .

Reproduction and redistribution require permission from the rights holder. /       .



CONTENTS / 

15 Chapters / 15 

01. ENGINE ROOM WATCHKEEPING & MACHINERY MONITORING      6

02. MAIN ENGINE OPERATION & COMMON PROBLEMS      15

03. AUXILIARY ENGINES & DIESEL GENERATORS      25

04. PUMPS & PIPING SYSTEMS      34

05. LUBRICATION SYSTEMS & OIL ANALYSIS      42

06. COOLING SYSTEMS & HEAT EXCHANGERS      50

07. FUEL OIL SYSTEMS & FUEL TREATMENT      59

08. BEARINGS & SHAFT ALIGNMENT      68

09. CAVITATION & PUMP TROUBLESHOOTING      76

10. PURIFIERS & SEPARATORS      84

11. BOILERS & COMPRESSED AIR SYSTEMS      93

12. BALLAST WATER TREATMENT & POLLUTION PREVENTION      102

13. ENGINE ROOM MAINTENANCE & PLANNED MAINTENANCE SYSTEM (PMS)      110

14. ENGINE ROOM TROUBLESHOOTING & EMERGENCY SITUATIONS      118

15. TECHNICAL COMMUNICATION, PSC INSPECTIONS & ENGINEER INTERVIEWS      127



BLC MARITIME ENGLISH

CHAPTER 1  |  ENGINE ROOM WATCHKEEPING & MACHINERY MONITORING

      




Learning Objectives /  


Learn to monitor machinery, report deviations, conduct watch handovers and communicate about alarms and corrective actions.



   ,   ,         .











1. Technical Reading /  


Engine room watchkeeping is an essential part of safe vessel operation.

   -     .

The engineer on watch monitors machinery performance and ensures that equipment operates within safe limits.

        ,      .

On vessels with periodically unattended machinery spaces, engineers must respond promptly to alarms and follow established UMS procedures.

                  UMS.

During an inspection, the engineer checks temperatures, pressures, fluid levels, vibration and unusual noises.

     , ,  ,    .

Any abnormal reading must be investigated and reported in accordance with the vessels procedures.

           .

A sudden drop in lubricating oil pressure may indicate leakage, pump failure or insufficient oil supply.

        ,      .

An unexpected increase in bearing temperature may indicate inadequate lubrication, excessive load or mechanical damage.

        ,     .

Never ignore an alarm or reset it without identifying the cause and following the approved procedure.

             .




2. Key Vocabulary /  




ENGLISH





Engineer on watch

 



Watch handover

 



Machinery space inspection

  



Operating parameters

 



Permissible limits

 



Abnormal reading

 



Lubricating oil pressure

  



Cooling water temperature

  



Bearing temperature

 



Pressure drop

 



Leakage





Excessive vibration

 



Alarm acknowledgement

 



Alarm reset

 



Corrective action

 



Engine room logbook

 



Standby pump

 



Unattended machinery space (UMS)

  



Set point





Investigate a fault

  



Deviation

 (  )



Abnormal parameter

    



Acknowledge an alarm

   



Proceed to the engine room

   




3. Watch Handover /  



Review the logbook and any outstanding defects before taking over the watch.

         .

Confirm the status of running and standby machinery.

     .

Check active alarms, isolated equipment and ongoing maintenance.

   ,        .

Clarify any unusual operating conditions and instructions from the Chief Engineer.

       .








1. Do not complete the handover until abnormal conditions are understood and properly reported.

   ,           .          .

2. Verify critical readings and active alarms yourself, as required by the watchkeeping procedure.

         ,   .

3. Ask which machinery is isolated, unavailable or under maintenance.

,   ,     .      .

4. Before handing over the watch, explain all outstanding defects, unusual conditions and instructions.

       ,    . ,    .












Interview Question / 


Under what circumstances must you refuse to take over an engine room watch?

          ?




Model Answer /  


I must not take over the engine room watch if I am not fit to perform my duties safely or if the relieving procedure has not been properly completed.

For example:

1. If an important operation is in progress and a safe handover cannot yet be completed.

2. If there is an emergency or a serious machinery malfunction that has not been properly explained.

3. If I have not received sufficient information about machinery condition, alarms, ongoing maintenance or special instructions.

4. If I am not fit for duty due to illness, fatigue or any other condition affecting my ability to work safely.

In such situations, I must inform the Chief Engineer and ensure that the watch is properly handed over before taking responsibility.




 / Translation


    ,  ,       ,          .

:

1.          .

2.        ,       .

3.         , - ,      .

4.        - ,    .

            ,    .




Professional Phrase to Remember /  


I am not ready to take over the watch until the situation has been clarified.

    ,     .




4. Watch Handover Drill:An Outstanding Fuel Leak / 


Outgoing Engineer: We have a fuel leak on No. 2 generator. The affected line has been isolated, and the generator is out of service.

 :      -  2.   ,    .

Incoming Engineer: Is the standby generator available? Do we have sufficient generating capacity?

 :   ?     ?

Outgoing Engineer: Yes. No. 1 generator is running, and No. 3 generator is available on standby.

 : . -  1 ,   3   .

Incoming Engineer: Has the Chief Engineer been informed? Istherepairscheduled?

 :   ?  ?

Outgoing Engineer: Yes. The defect is recorded in the logbook. The repair is scheduled for the next maintenance period.

 : .     .       .

Incoming Engineer: Let's verify the isolation status and check the generator availability before completing the handover.

 :       ,     .




? Lesson Learned /   


Never assume that an isolated fuel leak is no longer a concern. Confirm the equipment status, available generating capacity and outstanding repair work before taking over the watch.

 ,        .      ,       .




PracticalEnglish /     




Anything unusual during your watch?

-    ?



Any outstanding defects?

  ?



Which equipment is out of service?

    ?



Has the Chief Engineer been informed?

  ?



Is the standby generator available?

  ?



I need to clarify this before taking over.

      .



Lets check the readings together.

   .




5. Real-LifeSituation /   


You are about to take over the watch. The outgoing engineer says: The lubricating oil pressure on No. 2 generator has been dropping slowly. It is probably nothing. Just keep an eye on it.

   .   :     -  2  . ,  .  .

Task: Ask at least three questions in English. Explain what you need to verify and whom you would inform before completing the handover.

:       . ,          .




6. Practical Dialogue /  


Situation: A Third Engineer reports a rising bearing temperature on auxiliary engine No. 2. /          2.

Third Engineer: Chief, Ive noticed an increase in the No. 2 auxiliary engine bearing temperature.

 : ,        .

Chief Engineer: Whats the current reading?

 :   ?

Third Engineer: Its 85C. The normal operating temperature is around 65C.

 :  85 C.     65 C.

Chief Engineer: Have you checked the lubricating oil pressure?

 :     ?

Third Engineer: Yes. It is within the normal range, but the temperature is still rising.

 : ,    ,    .

Chief Engineer: Check the load and other bearing temperatures. Prepare the standby generator for use. Well follow the manufacturers instructions.

 :      .   .     .

ThirdEngineer: Understood. Ill report any further changes immediately.

 : .     .




Useful Phrases /  




All operating parameters are within the normal range.

      .



The lubricating oil pressure is dropping.

   .



The bearing temperature is gradually increasing.

   .



There is excessive vibration on the No. 2 generator.

 -  2   .



The standby pump is ready for operation.

    .



Ill investigate the cause and report back.

    .



The alarm has been acknowledged, but the fault is still present.

 ,     .



Ive recorded the readings in the engine room logbook.

     .



We are experiencing excessive vibration on the main engine.

     .




7. Troubleshooting Language /   


The pressure has dropped below the alarm set point.

    .

The temperature is rising despite normal oil pressure.

 ,     .

We need to verify the instrument reading before drawing conclusions.

   ,    .

The cause has not yet been confirmed.

   .

The equipment has been isolated in accordance with the approved procedure.

      .













A. Complete the sentences /  


Words: reported  cause  service  rising  range

1. The lubricating oil pressure has dropped below the normal ______.

2. We need to investigate the ______ of the alarm.

3. The standby generator is ready to be put into ______.

4. The bearing temperature is ______ steadily.

5. All abnormal readings must be ______.




B. Answer in English /  -


1. What parameters do you check during an engine room inspection?

2. What could cause a sudden drop in lubricating oil pressure?

3. What should you do if a bearing temperature starts rising?

4. What information should be included in a watch handover?

5. Why is it important to record abnormal machinery conditions?




C. Speaking Assignment /  


You are the Third Engineer. During an inspection, you notice that the cooling water temperature is rising. The standby pump is available. Report the situation to the Second Engineer.

  .         .   .   .

Speaking plan /  : identify the affected system ? state the abnormal reading ? describe the trend ? report checks completed (if any) ? ask for instructions.

D. UMS alarm response /    UMS

Situation: You are in your cabin when the UMS alarm sounds. The bridge calls you about a machinery alarm. Explain what you will do and what you will report.

:    ,    UMS.       .      .

Use: acknowledge the alarm ? proceed to the engine room ? identify the alarm ? investigate the cause ? report to the bridge and Chief Engineer ? follow vessel procedures.

:   ?     ?   ?   ?       ?    .

E. Present Continuous: reporting trends /   

Translate into English /   :

1.    .

2.    .

3.  .

4.  .

F. Pronunciation & listeningpractice /   

auxiliary /????z?li?ri/; deviation /?di?vi?e???n/; machinery /m???i?n?ri/; acknowledge /?k?n?l?d?/.

Read the UMS report aloud or record it on your phone. Listen back and check clarity, numbers, equipment names and stress. /   UMS     .  :   , ,    .




G. Self-Check / 


1. What does within the normal range mean?

2. How do you say   in English?

3. Explain the difference between acknowledging an alarm and resetting it.

4. Translate:    .

5. Write two sentences for reporting a rising temperature.








Exercise A  Answer Key /    A

1. The lubricating oil pressure has dropped below the normal range.

      .

2. We need to investigate the cause of the alarm.

    .

3. The standby generator is ready to be put into service.

      .

4. The bearing temperature is rising steadily.

   .

5. All abnormal readings must be reported.

     .

Exercise B  Model Answers /  

1. I check temperatures, pressures, fluid levels, vibration and unusual noises.

  , ,  ,    .

2. A sudden drop may be caused by leakage, pump failure or insufficient oil supply.

      ,      .

3. I check the reading and operating limits, report the trend and follow the approved procedures.

      ,         .

4. A handover includes machinery status, active alarms, abnormal readings, outstanding defects and maintenance work.

    ,  ,  ,    .

5. Records help identify trends and recurring faults and ensure continuity between watches.

          .

Exercise C  Speaking Assignment /  

Second Engineer, the cooling water temperature is rising. The standby pump is available. I am verifying the current reading and checking the cooling system parameters. I have not yet confirmed the cause. Please advise on further action.

 ,    .   .        .    .     .

ExerciseD  UMSAlarmResponse /  

I will acknowledge the alarm and proceed promptly to the engine room in accordance with the UMS procedures. I will identify the alarm, check the machinery condition, investigate the cause and report to the bridge and Chief Engineer as required.

            UMS.  ,   ,            .

Exercise E - Present Continuous / 

1. The lubricating oil pressure is dropping.

   .

2. The bearing temperature is still rising.

   .

3. Thevibrationisincreasing.

 .

4. The temperature is stabilizing.

 .

Exercise F  Pronunciation & Listening / Alternative Model Report /   

Bridge, this is the duty engineer. I have acknowledged the machinery alarm and am proceeding to the engine room. I will check the alarm indication and report the findings in accordance with the UMS procedure.

,   .          .          UMS.

Self-check: Sayequipmentnamesandnumbersclearly; checkstressinauxiliary, deviation, machineryandacknowledge. / :      ;     .

Exercise G - Self-Check / 

1. It means the parameter is within the specified acceptable operating limits.

      .

2. Watch handover.

 .

3. Acknowledging confirms receipt of an alarm; resetting clears the alarm indication when permitted by the system and procedure. Neitheractionalonefixestheunderlyingfault.

   ;   ,      .           .

4. The cause has not yet been confirmed.

   .

5. The bearing temperature is rising steadily. I am monitoring the trend and checking the operating limits.

   .       .

Section 5  Real-Life Situation /  

What is the current oil pressure? Has the Chief Engineer been informed? Is the standby generator available? I need to verify the reading and the manufacturers limits, clarify the abnormal trend and follow the vessels watchkeeping procedures before completing the handover.

   ?   ?   ?      ,  ,            .



BLC MARITIME ENGLISH

CHAPTER 2  |  MAIN ENGINE OPERATION & COMMON PROBLEMS

     




LearningObjectives /  


Learntodescribemainengineoperation, monitorcriticalparameters, reportabnormalities, discusspossiblecausesandcommunicatecorrectiveactions. /     ,  ,   ,      .











1. Technical Reading /  


The main engine provides the power required to propel the vessel.

   ,    .

Many merchant vessels use slow-speed two-stroke diesel engines directly coupled to the propeller shaft.

        ,     .

Engineers monitor lubricating oil pressure, cooling water temperatures, exhaust gas temperatures, scavenge air pressure and engine load.

    ,      ,      .

A significant difference in exhaust gas temperature between cylinders may indicate uneven combustion or another cylinder-specific problem.

                .

Possible causes include a faulty fuel injector, incorrect fuel delivery, poor compression or an exhaust valve problem.

 :  ,   ,      .

A drop in lubricating oil pressure requires prompt assessment because inadequate lubrication can damage bearings and other moving parts.

      ,          .

Engineers must compare readings with the manufacturers limits and the vessels operating procedures, rather than relying on universal values.

         ,      .

Any abnormal condition must be reported, investigated and recorded as required by the ships procedures.

    ,           .




2. Key Vocabulary /  




ENGLISH





main engine (ME)

 



two-stroke diesel engine

  



cylinder liner

 



piston rings

 



cylinder head

 



exhaust valve

 



fuel injector

 



fuel injection timing

  



scavenge air

 



turbocharger





charge air cooler

  



exhaust gas temperature (EGT)

  



lubricating oil pressure

  



jacket cooling water

   



engine load

 



cylinder imbalance

  



poor combustion

 /  



abnormal reading

   



to investigate a fault

  



to reduce engine load

  



to report the findings

  



corrective action

 



deviation





permissible range

 



manufacturers limit

,  



trend graph

  



temperature spike

  




3. Monitoring Parameters /  


Exhaust gas temperature is monitored for each cylinder and compared with the engines normal trend.

             .

Lubricating oil pressure must remain within the manufacturers specified limits.

      ,  .

Cooling water temperature and pressure help engineers assess the condition of the cooling system.

         .

Scavenge air pressure and temperature can provide information about air supply and turbocharger performance.

           .




4. Common Problems /  





Problem / 

Possible causes /  



Highexhaustgastemperature



   

Faulty fuel injector; combustion problems; overload; exhaust valve fault.



  ;  ; ;   .



Low lubricating oil pressure



   

Leakage; low oil level; pump fault; abnormal oil temperature.



;   ;  ;     .



Highjacketcoolingwatertemperature



     

Insufficient cooling; fouled cooler; cooling pump problem.



 ;  ;   .



Excessive vibration



 

Misfiring; mechanical defect; other machinery-related causes.



 ;  ;  ,    .










1. Before changing engine load, check the current operating conditions and any bridge instructions.

           .

2. Never judge engine condition from one reading alone. Compare trends, related parameters and the other cylinders.

      .  ,     .

3. A rising exhaust gas temperature may signal a developing fault. Report the trend promptly and follow the approved response procedure.

        .         .

4. Do not adjust fuel injection equipment without authorization and the makers instructions.

        .

5. Before starting maintenance, confirm the engine status, isolation arrangements and permit requirements.

    ,       .

6. Before handing over the watch, report abnormal trends, alarms, restrictions and outstanding defects.

      ,  ,    .




Practical English /  




ENGLISH





Is this temperature normal for the current engine load?

      ?



What was the reading during the previous watch?

     ?



Are the other cylinders within their normal operating range?

        ?



Has the Chief Engineer been informed?

  ?



Lets check the trend before making any adjustment.

     .



According to the manual, we must verify the alarm limits.

 ,     .












Real-LifeSituation /   


During your watch, cylinder No. 5 EGT starts rising while the other cylinders remain stable. A colleague says: It is probably just a sensor fault.

         5  ,      .  : ,   .

Task: AskthreequestionsinEnglish. Explain what you would check and whom you would inform. Do not assume the sensor is faulty without verification.

:     . ,     .      .




LessonLearned /   


An abnormal reading is a warning, not a diagnosis. Check the trend, verify the indication where safe and appropriate, report the condition and follow the makers and vessels procedures.

    ,    .  ,     ,           .




5. ProfessionalDialogue /  


Situation: During a routine round, the Second Engineer notices that the exhaust gas temperature of one cylinder is higher than usual. / :            .

2/E: Chief, the exhaust gas temperature on cylinder No. 5 is higher than usual.

2/E: ,       .

C/E: What is the current engine load? Are there any other abnormal readings?

C/E:    ?    ?

2/E: The engine load is about 70 percent. The other parameters are within normal limits.

2/E:    70 .     .

C/E: Compare the cylinder temperatures and check the recent trend. Weneedtoinvestigatethecause.

C/E:        .   .

2/E: Understood. I will check the records and report back.

2/E: .    .

C/E: Do not adjust the fuel equipment without following the approved procedure.

C/E:        .




6. Useful Phrases /  




The main engine is running normally.

   .



The exhaust gas temperature is rising.

   .



Cylinder No. 5 shows an abnormal reading.

     .



We need to check the trend and compare the cylinders.

     .



The lubricating oil pressure has dropped.

   .



I will investigate the cause and report back.

    .



We should follow the manufacturers instructions.

     .



The findings have been entered in the engine room logbook.

     .




7. GrammarinUse /   



Present Perfect for a change or result / Present Perfect    :

The pressure has dropped. -  .  The temperature has increased. -  .

Present Continuous for a developing trend / Present Continuous   :

The temperature is rising. -  .  The engine is vibrating more than usual. -    .











A. Complete the sentences /  



Words: injector  load  pressure  investigate  temperature

1. The exhaust gas ______ is increasing.

2. The lubricating oil ______ has dropped.

3. A faulty fuel ______ may affect combustion.

4. We must ______ the cause of the abnormal reading.

5. The engine ______ is approximately 70 percent.




B. Answer in English /  -



1. Which main engine parameters do you monitor during operation?

2. What could cause high exhaust gas temperature in one cylinder?

3. Why is low lubricating oil pressure dangerous?

4. What information should you report to the Chief Engineer?




C. Speaking Assignment /  



You are the Second Engineer. Report a rising exhaust gas temperature on one cylinder. Include the load, other readings, your proposed checks and a promise to report back. /   .        .  ,  ,      .




D. Manual & Limits /   



Task: Learn how to refer to the manufacturers instructions when reporting technical problems.

:          .




Step 1. Study the useful phrases /   


According to the manual, we must check the alarm settings.

 ,    .

The manufacturers limit is specified in the operating manual.

,  ,     .

This reading is outside the permissible range.

      .




Step 2. Translate into English /   


Use the phrases above. Write your answers before checking the Answer Key.

  .  ,     .

1.  ,    .

2.     .

3.     .




Step 3. Practical Situation /  


The exhaust gas temperature of cylinder No. 5 is increasing. You need to check the manufacturers operating limits.

     5 .      .

Complete the report using the phrases from Step 1.

 ,     .

1. According to the manual, we must check __________.

2. The manufacturers limit is specified in __________.

3. If the reading exceeds the limit, it is outside __________.




E. Listening & Pronunciation / 



Pronunciation: auxiliary /????z?li?ri/; injector /?n?d?ekt?(r)/; exhaust /???z??st/; deviation /?di?vi?e???n/.

Listening practice /  : Ask a partner to read the report twice, or record it and listen without looking at the text: Chief, cylinder No. 5 exhaust gas temperature is rising. Engine load is seventy percent. Other parameters are within normal limits. I will check the trend and report back. Write down the cylinder number, load, trend and next action. /          ,    .   ,  ,     .




F. Self-Check / 



1. What does EGT stand for? /   EGT?

2. Name two possible causes of high EGT in one cylinder. /    .

3. Translate:     .

4. Explain the difference: has increased and is increasing. /  .

5. What should you consult before taking corrective action? /       ?











Exercise A  Answer Key /    A


1. temperature; 2. pressure; 3. injector; 4. investigate; 5. load.




ExerciseB  ModelAnswers /     B


1. I monitor lubricating oil pressure, cooling water temperature, EGT, scavenge air pressure and engine load.

    ,      ,      .

2. Possible causes include a faulty injector, incorrect fuel delivery, poor compression or an exhaust valve problem.

 :  ,   ,      .

3. Low lubricating oil pressure can cause inadequate lubrication and damage to bearings and moving parts.

              .

4. I report the affected cylinder, current readings, engine load, recent trends, alarms and checks already completed.

   ,  ,  ,  ,     .




Exercise C  Model Answer /   


Chief, the exhaust gas temperature on cylinder No. 5 is rising. The engine load is about 70 percent, and the other parameters are within normal limits. I will compare the cylinder readings and review the recent trend. I will report the findings immediately.

,      .    70 ,     .        .   .




ExerciseD  AnswerKey & ModelReport /    


Step 2  Translation Answer Key /   : 1. According to the manual, we must check the oil pressure. 2. This reading is outside the permissible range. 3. The manufacturers limit is specified in the operating manual.

Step 3  Complete the Report: Answer Key / : 1. the exhaust gas temperature; 2. the operating manual; 3. the permissible range.

Model Report /  : According to the manual, we must check the exhaust gas temperature against the specified operating limit. The manufacturers limit is specified in the operating manual. If the reading exceeds that limit, it is outside the permissible range.

 ,         .       .     ,     .




Exercise E  Listening & Pronunciation Answer Key /     


Listening Check /   : cylinder No. 5; engine load 70%; exhaust gas temperature rising; check the trend and report back. /   5;  70%;    ;    .

Pronunciation Self-Check /  : auxiliary, injector, exhaust, deviation. Check word stress and clear pronunciation. /     .

Real-Life Situation  Model Answer /    

What is the current EGT on cylinder No. 5? How quickly is it rising? Have we checked the trend and the other cylinders? I would verify the indication according to the approved procedure and inform the Chief Engineer promptly.

      ?    ?      ?            .




ExerciseF  AnswerKey /   


1. EGT means exhaust gas temperature.

EGT    .

2. A faulty fuel injector or an exhaust valve problem.

       .

3. The other parameters are within normal limits.

    .

4. Has increased describes a change or result; is increasing describes a continuing trend.

Has increased    ; is increasing   .

5. Consult the manufacturers manual, alarm/shutdown requirements and the vessels approved procedures.

   ,  /    .



BLC MARITIME ENGLISH

CHAPTER 3  |  AUXILIARY ENGINES & DIESEL GENERATORS

   -




LearningObjectives /  


Learn to describe diesel generator operation, discuss load sharing and synchronization, report abnormal readings and communicate during generator changeover.

   -,     ,          .











1. Technical Reading /  


Auxiliary diesel generators supply electrical power for essential machinery, navigation equipment and accommodation services.

 -    ,     .

A diesel generator consists of a diesel engine coupled to an alternator.

-    ,     .

Before starting a generator, the engineer checks lubricating oil, cooling water, fuel supply and the condition of the starting system.

      ,  ,      .

After starting, the engineer monitors oil pressure, cooling water temperature, voltage, frequency and any abnormal noise or vibration.

     ,   , , ,      .

Before connecting an incoming generator to a live busbar, its voltage, frequency and phase relationship must meet the synchronization requirements.

         ,        .

When generators operate in parallel, active power is shared through the governors, while reactive power sharing depends on the excitation and voltage control systems.

          ,           .

A sudden loss of generating capacity may cause an overload or a blackout if the remaining generators cannot support the electrical demand.

          ,       .

All switching and changeover operations must follow the vessels approved procedures and the electrical safety requirements.

             .




2. Key Vocabulary /  




English





auxiliary engine

 



diesel generator / generator set

- /  



alternator

  



busbar

 



circuit breaker

 



synchronization





load sharing

 



active power (kW)

  ()



reactive power (kVAr)

  ()



frequency (Hz)

 ()



voltage (V)

 ()



governor

  



excitation system

 



standby generator

 



incoming generator

 



running generator

 



generator changeover

   



overload





reverse power

 



blackout

 



low lube oil pressure

   



high jacket water temperature

   



to close the breaker

  



to open the breaker

  




3. Normal Operating Checks /   


Check the lubricating oil pressure and cooling water temperature against the manufacturers operating limits.

           .

Monitor generator load, voltage and frequency on the switchboard.

  ,       .

Check for fuel, oil or cooling water leaks during routine rounds.

       ,    .

Report any unexpected fluctuation, alarm or abnormal vibration promptly.

      ,     .




4. Common Problems /  





Problem / 

Possible causes /  



Low lubricating oil pressure /   

Low oil level, leakage, pump fault or sensor problem /   , ,    



Highcoolingwatertemperature /    

Restricted flow, fouled cooler or pump fault /  ,     



Unstable frequency /  

Governor or fuel control issue; rapidly changing load /     ;   



Unevenloadsharing /   

Governor/load-sharing control issue or incorrect settings /       



Reversepoweralarm /   

Loss of prime-mover torque while connected in parallel /        










1. Before starting a standby generator, verify that it is ready according to the approved checklist.

         -.

2. Never close a generator breaker onto live busbars unless synchronization conditions and permissions are satisfied.

      ,          .

3. Monitor both active load (kW) and reactive load (kVAr) during parallel operation.

       (),    ().

4. Do not ignore unstable frequency or repeated breaker trips, even if no alarm is active.

       ,     .

5. Before transferring load, confirm that the receiving generator has sufficient capacity and is ready.

   ,         .

6. After a trip, report the alarm, affected consumers, available generation and actions taken.

      ,  ,     .




Practical English /  




What is the current load on the running generator?

    ?



Is the standby generator ready for automatic start?

     ?



The frequency is unstable, but no alarm is active.

 ,     .



The breaker has tripped. We are checking the cause.

   .   .



The emergency generator has started automatically.

   .



Non-essential loads have been shed.

    .



Power Sharing /  

The governor and load-sharing controls regulate active power (kW) and frequency.

          ()  .

The excitation and voltage-control systems regulate voltage and reactive power sharing (kVAr).

           ().

Real-LifeSituation /   

No. 1 generator trips while two generators are operating in parallel. No. 2 generator remains connected, and the standby generator is available. You do not yet know whether the remaining capacity is sufficient.

-  1        .   2  ,   .  ,    .

Task: In 45 English sentences, report the trip, current power situation, alarms, immediate checks and request for instructions.

:  45      ,  , ,     .

Lesson Learned /   

A standby generator being available does not mean that the ship has enough electrical capacity. Check the actual load, protection status and readiness before any switching.

      ,     .     ,     .




5. ProfessionalDialogue /  


Situation: The Third Engineer reports unstable frequency on a running generator. / :        .

3/E: Second Engineer, the frequency on No. 2 diesel generator is fluctuating.

3/E:  ,   -  2 .

2/E: What is the current load? Are there any alarms?

2/E:   ?  -  ?

3/E: The load is about 55 percent. There are no active alarms, but the frequency is unstable.

3/E:   55 .    ,   .

2/E: Check whether the electrical load is changing. Monitor the governor response and report the readings.

2/E: ,    .       .

3/E: Understood. Shall I prepare the standby generator?

3/E: .   ?

2/E: Yes, prepare it in accordance with the procedure. Do not transfer the load until we have assessed the situation.

2/E: ,    .   ,     .

3/E: I will keep monitoring and report any further deviation.

3/E:        .




6. Useful Phrases /  




English





The standby generator is ready for starting.

    .



The generator is running without load.

   .



The frequency is fluctuating.

 .



We need to check the load-sharing system.

    .



The incoming generator is not yet synchronized.

    .



The breaker has tripped.

    .



We have lost one generator.

    .



I will record the readings in the logbook.

    .




7. GrammarinUse /   



Present Continuous for changing conditions / Present Continuous   :

The frequency is dropping. -  .  The load is increasing. -  .

Present Perfect for completed events / Present Perfect    :

The breaker has tripped. -    .  We have started the standby generator. -    .











A. Complete the sentences /  

Words: frequency, standby, breaker, load, synchronized.


1. The ______ generator is ready for starting.

2. The ______ is fluctuating.

3. The circuit ______ has tripped.

4. We must monitor the generator ______.

5. The incoming generator has not been ______ yet.




B. Answer in English /   .


1. Which parameters do you check after starting a diesel generator?

2. What must be checked before connecting a generator to live busbars?

3. What can cause unstable generator frequency?

4. Why is correct load sharing important?

5. What should you report after a generator trips?




C. Speaking Assignment /  : You are the Third Engineer. No. 1 generator has tripped, and the standby generator is available. Report the event to the Second Engineer. Explain which alarms and power-supply details still need verification, and ask for instructions. Do not invent readings or assume another generator is supplying the switchboard. /   .   1   ,   .     . ,         ,   .      ,      .







D. BlackoutCommunication /   


Situation: The main switchboard has lost its normal supply. The emergency generator may have started, but this must be verified.

:      .    ,    .

Task: State what is known, what must be verified and whom you will notify. Donotassumepowerhasbeenrestored.

:   ,       .  ,    .

Use: blackout ? emergency generator status ? essential services ? report ? follow approved recovery procedure.

:  ?    ?     ?  ?   .




E. TranslateintoEnglish /   


1.   .

2.    .

3.    .

4.    .




F. Pronunciation & Listening /   


Practice: auxiliary /????z?li?ri/; synchronization /?s?nkr?na??ze???n/; frequency /?fri?kw?nsi/; excitation /?eksa??te???n/.

        Answer Key.     ,      .




G. Self-Check / 



1. The generator supplies electrical _____.  a) power  b) water  c) air

2. The governor mainly controls engine _____.  a) speed  b) cooling  c) filtration

3. A circuit breaker can _____ on a fault.  a) trip  b) lubricate  c) evaporate

4. Before parallel connection, generators must be _____.  a) synchronized  b) painted  c) drained

5. A blackout means loss of electrical _____.  a) supply  b) fuel viscosity  c) jacket water











Exercise A  Answer Key /  A


1. The standby generator is ready for starting.

    .

2. The frequency is fluctuating.

 .

3. The circuit breaker has tripped.

    .

4. We must monitor the generator load.

    .

5. The incoming generator has not been synchronized yet.

    .




Exercise B  Model Answers /  


1. I check lubricating oil pressure, cooling water temperature, voltage, frequency, load, noise and vibration.

   ,   , , , ,   .

2. I verify voltage, frequency and phase relationship and follow the synchronization procedure.

  ,        .

3. Unstable frequency may result from changing load or problems with the governor or fuel control.

             .

4. Correct load sharing helps prevent generator overload and unstable parallel operation.

          .

5. I report which generator tripped, alarms, remaining generation, affected consumers and actions taken.

 ,   ,   ,    ,      .




Exercise C  Model Report /  


Second Engineer, No. 1 diesel generator has tripped. The standby generator is available, but I have not yet confirmed the remaining power supply or the alarm details. I am checking the switchboard indications, active alarms and available generating capacity. I will follow the approved procedure. Please advise on further action.

 , -  1   .   ,           .     ,      .     .   .




ExerciseD  ModelReport /  


We have lost normal power on the main switchboard. I am verifying whether the emergency generator has started and which essential services have power. I will report the confirmed status to the bridge and Chief Engineer and follow the vessels blackout recovery procedure.

      .  ,            .                .




Exercise E - Translation / 


1. The generator frequency is fluctuating.

  .

2. The emergency generator has started automatically.

   .

3. Wehavelostonegenerator.

   .

4. We need to check the load sharing.

   .




ExerciseF - Pronunciation & Listening /  


  ,  ,        .




Exercise G - Self-Check / 


1. a) power - .

2. a) speed -  .

3. a) trip -   .

4. a) synchronized - .

5. a) supply - .



BLC MARITIME ENGLISH

CHAPTER 4  |  PUMPS & PIPING SYSTEMS

   




LearningObjectives /  


Describe common marine pump types and their operating principles; report loss of suction, cavitation, leakage and abnormal vibration; discuss safe isolation and troubleshooting.

        ;    , ,    ;      .











1. Technical Reading /  


Pumps transfer liquids through the vessels fuel oil, lubricating oil, cooling water, ballast and bilge systems.

     , , ,    .

Centrifugal pumps use a rotating impeller to increase the velocity of the liquid and convert part of that energy into pressure.

                .

Positive displacement pumps move a fixed volume of liquid during each cycle and are commonly used for viscous fluids.

              .

Before starting a pump, the engineer must check the line-up of valves, the liquid supply, lubrication, seals and the relevant operating instructions.

       ,  , ,      .

Many centrifugal pumps require priming before start-up; running a pump dry may damage the mechanical seal and other components.

       ;          .

A blocked suction strainer, air ingress or insufficient suction head may cause a loss of suction and reduced discharge pressure.

   ,             .

Cavitation occurs when local pressure falls below the liquids vapour pressure and vapour bubbles form and collapse in higher-pressure regions.

 ,         ,         .

Cavitation can cause noise, vibration, erosion of the impeller and a reduction in pump performance.

   , ,       .

Positive displacement pumps must be protected against excessive discharge pressure by suitable relief arrangements.

              .

Never open a pressurised line or dismantle a pump until it has been isolated, depressurised and made safe in accordance with the vessels procedures.

         ,    ,          .




2. Key Vocabulary /  




English





centrifugal pump

 



positive displacement pump

 



gear pump

 



screw pump

 



impeller

 



pump casing

 



suction line

 



discharge line

 



suction strainer

  



mechanical seal

 



gland packing

 



priming

    



loss of suction

 



air ingress

 



cavitation





flow rate

 / 



discharge pressure

 



pressure relief valve

 



non-return valve

 



isolation valve

 



leakage





dry running

 



differential pressure

 



pipework






3. OperatingChecks /   


Confirm that the correct suction and discharge valves are lined up.

,          .

Check the suction and discharge pressures and compare them with normal values.

           .

Listen for unusual noise and check for excessive vibration or leakage.

          .

Monitor bearing temperature, seal condition and motor load.

  ,     .

Record abnormal readings and report deviations promptly.

       .




4. Common Problems /  





Problem / 

Possible causes /  



Low discharge pressure /   

Blocked suction strainer, air ingress, worn impeller /  ,  ,   



Cavitation noise /  

Insufficient suction pressure, high liquid temperature, excessive flow /    ,   ,  



Sealleakage /   

Worn or damaged seal, incorrect installation /    ,  



High vibration /  

Misalignment, bearing damage, cavitation / ,  , 



Motor overload /  

Mechanical binding, unsuitable operating point, high viscosity /  ,   ,  










1. Before starting a pump, confirm the valve line-up and that the system is ready for operation.

          .

2. Never assume a standby pump is ready. Check its availability and the approved changeover arrangements.

      .      .

3. If suction pressure falls, check the readings and possible restrictions before assuming the pump itself is faulty.

          ,     .

4. Do not continue operating a pump with severe vibration or suspected cavitation without assessing the risk and following the vessels procedures.

                 .

5. Never open a strainer or pipework until isolation, depressurisation and other required safety measures are verified.

     ,    ,       .

6. During watch handover, report leaks, abnormal trends, isolated equipment and unfinished maintenance.

     ,  ,     .




Practical English /  




Has the standby pump been tested?

  ?



What was the suction pressure before the fault?

      ?



Is the strainer differential pressure increasing?

     ?



Has the duty engineer been informed?

  ?



Is the line isolated and depressurised?

    ?




Real-LifeSituation /   


During your watch, a seawater cooling pump begins to vibrate and its discharge pressure drops. A colleague says: It is probably just the strainer. Open it and check.

        ,    .  : ,   .   .

Task: Report the symptoms, identify what you need to verify, and explain why you must not open the strainer immediately. Write 45 Englishsentences.

:    ,     ,     .  45   .




Lesson Learned /   


A high strainer differential pressure may suggest a restriction, but it does not prove the cause. Confirm the equipment condition and follow isolation and permit-to-work procedures before intervention.

        ,    .           -.




  .


   .

   ,     (https://www.litres.ru/book/larisa-brovtsina-34125518/engine-room-english-74839379/)  .

      Visa, MasterCard, Maestro,    ,   ,     ,  PayPal, WebMoney, ., QIWI ,       .